    • isaziI Offline
      isazi Moderator @Fatih Kale
      last edited by

      @Fatih-Kale said in Smart sensor:

      @Egika Thank you for the clarification.

      I am not sure about choosing the HR source but I think when chest strap is connected it is prioritized. If there is no chest strap then wrist HR is measured.

      Yes, this is the behavior I also noticed.

      Watch: Suunto Vertical Ti

      Blog: isazi's home

      1 Reply Last reply Reply Quote 0
      • freeheelerF Offline
        freeheeler @Egika
        last edited by

        @Egika said in Smart sensor:

        Plus I am not sure how to select the chest belt as a HR source in favor of the wrist sensor

        I wonder how that works.
        If you select activity without HR then neither OHR nor the belt will be recorded. If you select with HR then only OHR will be showing the values. But does the belt overwrite OHR values later? Then it wouldn’t make sense that for swimming OHR is active…?! Should be a toggle instead of automatic recognition.
        I don’t use it in the water but I’d like to know because of interest.

        …by the way, I like the automatic recognition 👍

        living sideways

        Brad_OlwinB 1 Reply Last reply Reply Quote 0
        • Brad_OlwinB Offline
          Brad_Olwin Moderator @freeheeler
          last edited by

          @TELE-HO @Egika If you start the activity with the belt on, the belt will have priority and if the signal is lost the belt will cache (it can record 2-3h of HR data) and resync with the watch (i.e. when you get out of the water). If you take the belt off during the activity there will be no HR recorded as it does not switch to OHR. I often start gym activities with the watch and belt and leave my watch in the locker, when I return the HR data are synced to the activity.

          Vector/T6c/Ambit 3 Peak/S5 Copper/S3/S7 Ti/S9 baro Ti/S9P Ti/S9PP Ti/Vertical Ti/Race Ti/RaceS/Ocean/Wing

          EgikaE 1 Reply Last reply Reply Quote 2
          • EgikaE Offline
            Egika Platinum Member @Brad_Olwin
            last edited by

            @Brad_Olwin
            Now still the question is open why the wrist sensor starts flashing during an activity that was started with the chest sensor…?!

            t6, S6, Elementum Terra, Ambit 3 Sapphire, Spartan Ultra Copper, Traverse Alpha, S7 Graphite LE, S9B Ambassador, S9P Granite Blue Titanium, S9PP Titanium Sand, Vertical All Black, Race Titanium Charcoal,
            Race S All Black - TI Canary - Titanium Courtney

            Fatih KaleF Brad_OlwinB 2 Replies Last reply Reply Quote 0
            • Fatih KaleF Offline
              Fatih Kale @Egika
              last edited by

              @Egika maybe I was mistaken with the OHR readings when I was in the water. Brad knows better the watches.

              Suunto 9 Baro

              1 Reply Last reply Reply Quote 0
              • Brad_OlwinB Offline
                Brad_Olwin Moderator @Egika
                last edited by

                @Egika I will have to check this, it should not. It may flash for a moment until you see the HR symbol with the belt indicating HR is being read from the belt. The LEDs should stop once the connection occurs. There were issues with older firmware where the LEDs would continue but I believe that was fixed awhile ago.

                Vector/T6c/Ambit 3 Peak/S5 Copper/S3/S7 Ti/S9 baro Ti/S9P Ti/S9PP Ti/Vertical Ti/Race Ti/RaceS/Ocean/Wing

                S 1 Reply Last reply Reply Quote 1
                • S Offline
                  Shrek3k @Brad_Olwin
                  last edited by

                  @Brad_Olwin said in Smart sensor:

                  @Egika I will have to check this, it should not. It may flash for a moment until you see the HR symbol with the belt indicating HR is being read from the belt. The LEDs should stop once the connection occurs. There were issues with older firmware where the LEDs would continue but I believe that was fixed awhile ago.

                  Exactly the same experience with my S9 when using an external HF-band: flashing OHR-sensor on the watch during the initial phase, until the external sensor is identified. Then the OHR is deactivated and won’t reactivate during that activity.

                  using a Suunto Vertical & Suunto Wings; mostly running (AKA stomping around) and cycling mostly through the northern german "wilderness"
                  OS - Android 15/Pixel Pro 7

                  1 Reply Last reply Reply Quote 1
                  • Fatih KaleF Offline
                    Fatih Kale
                    last edited by Fatih Kale

                    Hi all,

                    Once again I have another issue with my smart sensor.

                    I sometimes see peaking in HR at the beginning of my runs. I know that the HR is wrong as I am going slow at the beginning but I read around 190 bpm. After first 4 5 mins readings get corrected and no issues are observed but first 5 mins mess all the metrics of the training.
                    I copied some screenshots below.

                    You can see that at the beginning I always see peaking but my HR should be around 130 bpm.

                    I always wet the belt before I start training.
                    I am soaking belt into water after every run.

                    link text

                    link text

                    link text

                    Suunto 9 Baro

                    zadowZ 1 Reply Last reply Reply Quote 0
                    • zadowZ Offline
                      zadow @Fatih Kale
                      last edited by zadow

                      @Fatih-Kale Hi, well, there could be a billion reasons for that. You’d find around here tons of discussions why the hell the HR reading from Smart Sensor is like this and that. First of all, and most likely reason is, that your strap is dying. However, before you buy a new strap, replace battery in the Smart Sensor. If that won’t help, you probably need a new strap. However, there might be another reason, as I discovered just yesterday and mentioned here in different thread. Your Smart Sensor may be broken. It happened to me. I replaced three straps within one year due to wrong readings from the belt. I was so convinced that strap is guilty for bad readings that I was only replacing them and did not check the sensor. Anyway, at the end, I sent sensor to Suunto (via local Suunto store) and Suunto immediately gave me a new sensor with note, that the old one was defective.

                      Suunto S9 Baro Titanium, Ironman l.e.
                      Suunto Smart Sensor
                      Wahoo Tickr FIT
                      Hammerhead Karoo 2

                      Swim Ride Run Rest Repeat

                      Fatih KaleF 1 Reply Last reply Reply Quote 3
                      • Fatih KaleF Offline
                        Fatih Kale @zadow
                        last edited by

                        @zadow thanks, belt or battery should not be dead yet I believe. I bought it 2 months ago. Life of belt should not be that short huh?

                        Suunto 9 Baro

                        zadowZ 1 Reply Last reply Reply Quote 0
                        • zadowZ Offline
                          zadow @Fatih Kale
                          last edited by zadow

                          @Fatih-Kale well, keep washing the belt after each run, also don’t forget to wash sensor’s connectros after each use. You’ll prolong it’s lifetime. How long it will last then…hard to tell. One more thing came to my mind. I do not know, where you live, but in my location, is currently autumn and temperature is decreasing rapidly. It’s freezing in the mornings. Low temperature also affects HR reading from straps. So, if you put your belt on inside, then you go outside, where the temperature is really low, it may take few minutes to warm up the sensor again for proper readings.

                          Suunto S9 Baro Titanium, Ironman l.e.
                          Suunto Smart Sensor
                          Wahoo Tickr FIT
                          Hammerhead Karoo 2

                          Swim Ride Run Rest Repeat

                          Fatih KaleF 1 Reply Last reply Reply Quote 2
                          • Fatih KaleF Offline
                            Fatih Kale @zadow
                            last edited by

                            @zadow that’s a lot of useful information thank you. I usually wear the belt inside and weather is usually 10 C low outside so this may explain why. Cheers

                            Suunto 9 Baro

                            F 1 Reply Last reply Reply Quote 2
                            • F Offline
                              fleshymutant Silver Members @Fatih Kale
                              last edited by

                              @Fatih-Kale one more thing, especially in winter would be to also moisten your skin as well as the belt. The belt relies on conductivity so until you begin to perspire the conductivity of your skin is poor.

                              Suunto 9 Baro Titanium
                              iOS 13.1

                              1 Reply Last reply Reply Quote 0
                              • fejkerF Offline
                                fejker Gold Members
                                last edited by

                                A friend of mine also gets these 200 bpm spikes at the start of activities … new watch, new belt, new sensor, wets the belt properly before start but the spikes at start are quite random. I myself have had some issues with the sensor, but mostly flatlines at the start of recording for a couple of minutes or occasional spikes over 200 bpm (which are an abnormality for me).

                                SHUT UP LEGS!
                                -Jens Voigt

                                1 Reply Last reply Reply Quote 1
                                • DarquD Offline
                                  Darqu
                                  last edited by

                                  I observe same things with sensor. Peaks, drop downs, no HR measurement randomly. I’ve got belt replaced by suunto service, worked well for a while but it happens again. Any update if it got fixed?

                                  Also… How I can update firmware in smart sensor?

                                  Cheers!

                                  Brad_OlwinB ? 2 Replies Last reply Reply Quote 0
                                  • Brad_OlwinB Offline
                                    Brad_Olwin Moderator @Darqu
                                    last edited by

                                    @Darqu No firmware updates AFIAK, I am using the sensor I bought with an A3P, many years ago. The belts have had the contact area recently redesigned. If the area where the sensor attaches is black you have an older belt, the newer ones have a grey area where the sensor attaches. The newer belts should last a long time and are available at the Suunto store online.

                                    Vector/T6c/Ambit 3 Peak/S5 Copper/S3/S7 Ti/S9 baro Ti/S9P Ti/S9PP Ti/Vertical Ti/Race Ti/RaceS/Ocean/Wing

                                    DarquD 1 Reply Last reply Reply Quote 0
                                    • ? Offline
                                      A Former User @Darqu
                                      last edited by

                                      @Darqu said in Smart sensor:

                                      I observe same things with sensor. Peaks, drop downs, no HR measurement randomly. I’ve got belt replaced by suunto service, worked well for a while but it happens again. Any update if it got fixed?

                                      Also… How I can update firmware in smart sensor?

                                      Cheers!

                                      https://www.facebook.com/groups/SuuntoAmbit/permalink/2708821062543273

                                      See if you can see the instructions

                                      1 Reply Last reply Reply Quote 0
                                      • DarquD Offline
                                        Darqu @Brad_Olwin
                                        last edited by Darqu

                                        @Brad_Olwin does new belt work with ‘old’ smart sensor? I will consider changing it.

                                        @André-Faria sure, I see, tried that way but no option to check firmware update is visible.

                                        EgikaE 1 Reply Last reply Reply Quote 0
                                        • EgikaE Offline
                                          Egika Platinum Member @Darqu
                                          last edited by

                                          @Darqu said in Smart sensor:

                                          @Brad_Olwin does new belt work with ‘old’ smart sensor? I will consider changing it.

                                          Yes, it does. And since the sensor itself has not changed, it is the only working combination

                                          t6, S6, Elementum Terra, Ambit 3 Sapphire, Spartan Ultra Copper, Traverse Alpha, S7 Graphite LE, S9B Ambassador, S9P Granite Blue Titanium, S9PP Titanium Sand, Vertical All Black, Race Titanium Charcoal,
                                          Race S All Black - TI Canary - Titanium Courtney

                                          1 Reply Last reply Reply Quote 1
                                          • ? Offline
                                            A Former User
                                            last edited by

                                            I use this old topic to avoid creating a new one.
                                            does the memory function of the suunto smart sensor also work with SA? it seems not…

                                            1 Reply Last reply Reply Quote 0
                                            • First post
                                              Last post

                                            Suunto Terms | Privacy Policy