    Mandatory Gas Time Alarm at beginning of the dive

    Scheduled Pinned Locked Moved Nautic
    79 Posts 11 Posters 8.1k Views 12 Watching
    Loading More Posts
    • Oldest to Newest
    • Newest to Oldest
    • Most Votes
    Reply
    • Reply as topic
    Log in to reply
    This topic has been deleted. Only users with topic management privileges can see it.
    • N Offline
      Nandodiver Bronze Member @hhouter
      last edited by Nandodiver

      @hhouter do you have the problem in :

      Sunnto Tank POD (new version)

      Or the

      Suunto wireless tank pressure transmitter (old version)

      H 1 Reply Last reply Reply Quote 0
      • H Offline
        hhouter Bronze Member @Nandodiver
        last edited by hhouter

        @Nandodiver I have the tank POD, i believe the transmitter only works with the older computers like Vyper and the D Range of dive watches.
        I bought the POD in the beginning of this year and i’m not aware that there is a new version available.

        1 Reply Last reply Reply Quote 1
        • N Offline
          Nandodiver Bronze Member
          last edited by Nandodiver

          This morning i had 2 x Mandatory gas alarm with both dive computers connect to the same transmitter and completely diferent times

          1x Nautic (right arm) (battery 45% )
          1x Nautica S (left arm) (battery 18% )
          1x transmitter on right side (backmount)

          and from my findings i believe is related with bad communication between transmitter and dive computer

          Ps: its the first time im using the configuration single gas tank, my normal configuration is multiple gas (even if both tanks are air ) Could be related or not with the alert/bad communication.

          pps: this was the dive i had most dropouts (no idea why)

          NAUTIC S

          Mandatory gas alarm 7m26s
          Air consumption 100L/Minute 7m31s
          Dropouts time on Nautic S 8m41s + 9m.28s + 26m49s + 27m21s + 29.26s

          Theres was some Dropouts that i didn’t record, not sure if was at same time has the Mandatoy gas alarm

          NAUTIC

          Mandatoy gas alarm 26m28s
          Air consumption 100L/Minute 26m28s
          Dropouts time on Nautic 9m19s + 26m43s + 27m20s + 29m24s.

          S1.png

          N1.png

          1 Reply Last reply Reply Quote 2
          • N Offline
            Nandodiver Bronze Member
            last edited by Nandodiver

            More prints

            S2.png

            N2.png

            H 1 Reply Last reply Reply Quote 2
            • N Offline
              Nandodiver Bronze Member
              last edited by Nandodiver

              more prints

              S3.png

              N3.png

              1 Reply Last reply Reply Quote 2
              • N Offline
                Nandodiver Bronze Member
                last edited by Nandodiver

                Here the Nautic S had dropout and i move the arm closer to the transmitter to re-connect

                NS 4.png

                1 Reply Last reply Reply Quote 1
                • N Offline
                  Nandodiver Bronze Member
                  last edited by

                  here Nautic & Nautical S had dropout at same time, and i was able to check the air consumption in Nautic

                  NS5.png

                  1 Reply Last reply Reply Quote 2
                  • N Offline
                    Nandodiver Bronze Member
                    last edited by

                    Another dropout Nautic & Nautical S

                    NS6.png

                    1 Reply Last reply Reply Quote 2
                    • N Offline
                      Nandodiver Bronze Member
                      last edited by Nandodiver

                      The following air consumption is not making sense on the Nautic S
                      Tank 12 L x 197 bar = 2364 bar

                      start 197 Bar
                      end 43 Bar
                      154 Bar x 12L =1848
                      2.70 ATM x 44 minutes = 118

                      1848L / 118 =15,6L minute

                      ns8.png

                      1 Reply Last reply Reply Quote 0
                      • H Offline
                        hhouter Bronze Member @Nandodiver
                        last edited by

                        @Nandodiver This is why I think, the POD does not have anything to do with it, somewhere in the Ventilation and GasTime calculation as seen by @mikenizm something goes crazy, it is corrected after some time but this is a serious issue to be solved asap!!!

                        N 1 Reply Last reply Reply Quote 1
                        • N Offline
                          Nandodiver Bronze Member @hhouter
                          last edited by

                          @hhouter the air consumption is definitely a bug (starting new topic about it)

                          H 1 Reply Last reply Reply Quote 1
                          • H Offline
                            hhouter Bronze Member @Nandodiver
                            last edited by hhouter

                            @Nandodiver Correct, but might also be related to the Ventilation issue…

                            L 1 Reply Last reply Reply Quote 0
                            • L Offline
                              l.sillsuunto @hhouter
                              last edited by

                              Since Suunto still shows no meaningful response and reports of Nautic issues keep piling up, I have now reported the Nautic through the European product safety system as a potentially dangerous product.

                              Given the false mandatory gas-time alarms and other incorrect dive data, I think an independent safety review is overdue.

                              I’ll keep you updated.

                              Screenshot 2026-08-10 164007.png

                              1 Reply Last reply Reply Quote 7
                              • J Offline
                                jozzz999 @hhouter
                                last edited by

                                @hhouter I had the same issue this morning on my Ocean. Freaked me out a bit. I was 17.5m down, shortly after starting the dive. Interestingly looking at my gas consumption graph in the app, it spiked through the roof momentarily when the Mandatory Gas Time alarm fired. Definitely a bug

                                H 1 Reply Last reply Reply Quote 3
                                • N Offline
                                  Nandodiver Bronze Member
                                  last edited by Nandodiver

                                  Since my latest findings, im starting to get a conclusion based on what I’ve observed (some of you might not be on the same opinion)

                                  Nautic - No dropouts > No issues (air consumption or alerts)
                                  Nautic - With dropouts > issues air consumption & alerts

                                  Nautic S - No dropouts (sidemount ) NO ISSUES watch & transmitter are close by
                                  Nautic S - with dropouts (backmount ) ISSUES since the watch is opposite side of transmitter

                                  Captura de ecrã 2026-08-17, às 10.28.32.png

                                  Captura de ecrã 2026-08-17, às 10.36.56.png

                                  N 1 Reply Last reply Reply Quote 1
                                  • N Offline
                                    Nandodiver Bronze Member @Nandodiver
                                    last edited by Nandodiver

                                    So did 2 dives this morning (maximum depth 11m)

                                    Nautic - new firmware 2.55.46
                                    Nautic S - 2.54.12
                                    transmiter on Right Side

                                    Air consumption seems to be correct in Nautic & Nautic S

                                    1st dive Nautic S had no dropouts or alerts (Left arm)
                                    1st dive Nautic no droputs or alerts (right arm)

                                    2st dive Nautic S no dropouts or alerts ( right arm)
                                    2st dive Nautic no dropouts or alerts (right arm)

                                    In more and more convinced the issues some people have are due transmitter bad connection with their computer, and is more noticeable at great depths

                                    Captura de ecrã 2026-08-20, às 23.51.40.png

                                    N 1 Reply Last reply Reply Quote 1
                                    • N Offline
                                      Nandodiver Bronze Member @Nandodiver
                                      last edited by Nandodiver

                                      One more dive without dropouts and the Time gas alarm is nowhere to be seen

                                      My findings and observations for that Time gas alarm at beginning of the dive is due the dropouts and bad connection between dive computer and the transmitter…

                                      Doing sidemount never had issues or bugs, with backmount i use both computers on the same wrist…

                                      Even the air consumption was very similar in Nautic /Nautic S

                                      Captura de ecrã 2026-08-22, às 23.03.46.png

                                      Captura de ecrã 2026-08-22, às 22.47.22.png

                                      N 1 Reply Last reply Reply Quote 1
                                      • N Offline
                                        Nandodiver Bronze Member @Nandodiver
                                        last edited by

                                        This tips comes from several dive computers manufactures to avoid Dropouts…

                                        When a dive light causes a wireless tank transmitter to drop its signal or fail underwater, it is usually due to electromagnetic interference (EMI) or radio frequency interference (RFI) emitted by the light’s internal LED driver circuit, or a shared power drop if batteries are critically low.

                                        TIPS

                                        Increase Distance: Keep your primary dive light mounted on your Goodman handle or hand, well away from the tank transmitter on your first stage or the computer on your wrist.

                                        Check Batteries: Swap or fully charge the batteries in both the dive light and the transmitter. Low voltage changes the operating frequency and output power of electronic circuits, making them much more susceptible to noise and drops.

                                        Use a HP Hose Extension: Move the transmitter off the direct port of the first stage using a short high-pressure hose extension. This clears physical and electronic blind spots.

                                        Upgrade Gear: Switch to a high-quality, name-brand dive light with certified electromagnetic compatibility (EMC) shielding, or service/replace an aging transmitter.

                                        My dive lights usually are:
                                        2x Divevolk LS50 ( video lights mounted on Gopro) away from transmitter.
                                        1x Wurkkos LS05 ( torch bolt snap attached to Nautic Bungee cord)
                                        1x Prozhaozhu ( strobe beacon bolt snap attached to Nautic Bungee cord)

                                        Curious: coincidence or not, when i stop using cheap TDS DZENOT backup light the dropouts stop

                                        1 Reply Last reply Reply Quote 0
                                        • H Offline
                                          hhouter Bronze Member @jozzz999
                                          last edited by hhouter

                                          @jozzz999 I did a comparison of two similair dives with the Nautic different firmwares (Claude AI). Location, depth anf time are moreless the same.

                                          Comparing the two logs (same device, firmware upgraded from 2.49.32 on Aug 9 to 2.55.46 on Aug 23):

                                          Structure is the same — both nest Ventilation inside each Cylinders[] entry, mixed in with Pressure, on the gas-0 (main tank) samples. No schema change there.

                                          But the logging pattern changed noticeably:

                                          Aug 9 (fw 2.49.32) Aug 23 (fw 2.55.46)
                                          Gas-0 samples 474 473
                                          Both Pressure & Ventilation in same sample 465 (98%) 421 (89%)
                                          Pressure logged, Ventilation null 5 42
                                          Ventilation logged, Pressure null 4 10
                                          Zero-ventilation readings 5 10
                                          Value range (nonzero) 0.000137–0.000554 0.00014–0.000529

                                          Key differences:

                                          1. Co-logging dropped off. On the older firmware, pressure and ventilation were almost always reported together in the same sample. On the newer firmware, they’re split apart much more often — 52 samples (11%) carry only one of the two fields, versus 9 samples (2%) on the older version. The measurement range itself didn’t change, just how consistently both values land in the same record.

                                          2. Twice as many zero-dropouts, despite nearly identical sample counts (474 vs 473). That suggests the newer firmware either drops more ventilation samples or is more prone to zero readings at depth.

                                          3. Dropout clustering differs. Aug 9 has one back-to-back double-dropout (two zeros 2 seconds apart at 29 m — the deepest point of that dive). Aug 23 has no back-to-back zeros, but its 10 dropouts are spread more broadly across the whole dive, including two right at the surface near the start (depth ~1.2 m, where a zero reading is plausible rather than a fault).

                                          Takeaway: the underlying ventilation calculation looks stable (same value range, same warm-up delay before the first reading appears), but the newer firmware is logging it less reliably alongside pressure and dropping to zero roughly twice as often — worth flagging as a possible regression if you’re tracking data completeness across firmware versions.

                                          H 1 Reply Last reply Reply Quote 1
                                          • H Offline
                                            hhouter Bronze Member @hhouter
                                            last edited by hhouter

                                            This is the log comparison for the Nautic and the EON Core on the same dive this morning 23/08/2026 +/- 9 AM. I didn’t sync the EON Core before the dive, that explains the hour difference as last dive was in the winter.

                                            NOTE:

                                            • 1 Single POD (Left on my 1st Stage)
                                            • Nautic (New Firmware) on my Left Arm
                                            • EON Core on my right arm

                                            That’s the real story here — these two logs are from two entirely different dive computers, not the same device on different dives. That changes what “logging accuracy” comparison actually means.

                                            Device identification:

                                            09:01:45 file 08:01:49 file
                                            Device “Vaasa” (Suunto-style), SW 2.55.46 “EON Core”, SW 4.0.1131
                                            Serial 254610001470 1953100087
                                            Schema Nested — Ventilation inside Cylinders[], alternating with Pressure Flat — Ventilation as its own top-level sample field

                                            Ventilation logging accuracy:

                                            Metric Vaasa (09:01) EON Core (08:01)
                                            Ventilation coverage 431/473 (91.1%) 422/446 (94.6%)
                                            Pressure & Ventilation co-logged in same sample 89.0% 94.4%
                                            Zero-value (likely dropout) readings 10 (2.3% of present) 0 (0.0%)
                                            Sample interval consistency 0–10.2s (one 0.0s duplicate) 9.8–10.0s, very tight
                                            Timestamp gaps >15s 0 0
                                            Nonzero value range 0.000140–0.000529 0.000133–0.000555

                                            Assessment:

                                            • The EON Core log is more accurate/reliable: higher ventilation coverage, tighter and more consistent co-logging of pressure with ventilation, zero dropout events, and a cleaner sample cadence.
                                            • The Vaasa log has real data-quality issues: 10 zero-ventilation dropouts mid-dive at depth (physiologically implausible), a lower field-coverage rate, and a stray 0.0-second duplicate timestamp — all consistent with the sensor/logging quirks flagged in the earlier Vaasa-only analyses.
                                            • Both devices measure ventilation on the same order of magnitude and unit scale, so the underlying sensor readings are comparable — the difference is purely in how completely and cleanly each device logs the field, not in what it’s measuring.

                                            Bottom line: if you’re trusting ventilation data for analysis, the EON Core’s log is the more accurate/complete of the two; the Vaasa log needs the dropout samples filtered or interpolated before use.

                                            N 1 Reply Last reply Reply Quote 1

                                            Hello! It looks like you're interested in this conversation, but you don't have an account yet.

                                            Getting fed up of having to scroll through the same posts each visit? When you register for an account, you'll always come back to exactly where you were before, and choose to be notified of new replies (either via email, or push notification). You'll also be able to save bookmarks and upvote posts to show your appreciation to other community members.